Fasting Diagnostic HPLC HbA1c Analyzer Fully Automated 5uL In Whole Blood Mode

Brand Name : LABNOVATION

Model Number : LD-560

Certification : IFCC, NGSP, CE

Place of Origin : Shenzhen, China

MOQ : 1 Unit

Price : USD7,000.00-12,000.00/Unit

Supply Ability : 100 Units/Day

Delivery Time : 15-20 working days

Packaging Details : Carton Size: 480mm×480mm×615mm, Gross Weight: 28kgs

Principle : HPLC (High Performance Liquid Chromatography)

Test Speed : 90s/test

Sample types : Whole blood or Pre-diluent sample

Test blood volume : 5μL in whole blood mode 150μL in pre-diluted mode

Sample capacity : 20 samples

Data storage : 5000

CV : <2%

Test range : 3.0%~18.0%

Dimensions : 378(L) ×380(W)×510(H)mm

Shelf Life : 5 years

Contact Now

Analyzer for HbA1c Testing HPLC Method Fasting Diagnostic Hba1c Fully Automated Analyzer

Intended use
The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood.
Principle
Using high performance liquid chromatography (HPLC), the stationary phase used is a weakly acidiccation exchanger. Glycosylation of hemoglobin will result in the loss of cations on the surface of hemoglobin without being charged, and non glycosylated hemoglobin has a positive charge. According to the different charged properties of hemoglobin, eluents with different pH values and ionic strengths are used sequentially, and several hemoglobin components including HbA1c are separated by high performance liquid chromatography. Each component is detected by a single wavelength colorimeter, and the detected data is processed by a computer to calculate the percentage content of HbA1c in the total hemoglobin.

Specification


Instrument Manufacturer Lanovation
Manufacture place China
Model LD-560
Dection information Principle HPLC
Detection method Dual wavelengh colorimetry
Wavelength 420nm
Test time 90 Seconds
Test Speed throughtput 40 samples per hour
Sample information Sample types Whole blood or Pre-diluent sample
Test blood volume 5μL in whole blood mode
150μL in pre-diluted mode
Sample capacity 20 samples
Sample loading method Continuous automatic sample loading
Mixer No, but probe mixing samples
Reagent and other consumble Column test quantity 3000
Reagent pack 600T(Reagent)/ 3000T(Column) separate
Eluent 2
Operation and character information Operation screen 10 inch Full color LCD display
Data storage 5000
Built-in Thermal Printer Yes
Performance information CV <2%
Test range 3.0%~18.0%
 
Package Information
Dimensions 378(L) ×380(W)×510(H)mm
Weight 28kg

Warning

  • This instrument is only intended for use by the physicians or qualified professionals trained by Labnovation or Labnovation’s agents.
  • This instrument can only carry out the instrument inspection service or any spare parts service provided by Labnovation or Labnovation’s agents.
  • It is important for the hospital or organization that uses this instrument to execute a reasonable service/maintenance plan. Neglect of service/maintenance may cause instrument breakdown or injury to human health.
  • If any problem occurs, please perform the troubleshooting procedures in accordance with Chapter 8. If the problem still exists, please contact the Labnovation service department for help.
  • Please make sure that this analyzer is used under the conditions specified in the instruction manual. The incorrect instruction may result in abnormal operation of the analyzer, unreliable measuring results, and possibly cause damage to parts of the analyzer or even personal injury.
  • The instrument should be inspected strictly before unpacking. In order to avoid breakage in transportation, the instrument is carefully packaged. When receiving the analyzer, please carefully check if there is physical damage in the packaging. If the packaging is damaged, please contact our services personnel.


Reagents and Consumables

The analyzer is recommended to be used in conjunction with the Glycosylated Hemoglobin Test Reagent Kit (high performance liquid chromatography (HPLC method)) produced by our company, which includes the following components:
Eluent A/Eluent B/Eluent C(Variant Mode) Adjusts the pH of the solution for the elution of glycosylated hemoglobin and non glycated hemoglobin.
Hemolysis Reagent Used to dissolve red blood cells and release hemoglobin.
Chromatography Column Used for separation and elution of glycosylated hemoglobin and non glycated.
Hemoglobin Filter Used to initially filter the sample after hemolysis.
Paper Rolls Prints a report of the test results.
Fasting Diagnostic HPLC HbA1c Analyzer Fully Automated 5uL In Whole Blood Mode

Exhibition

Fasting Diagnostic HPLC HbA1c Analyzer Fully Automated 5uL In Whole Blood Mode


Product Tags:

HPLC HbA1c Analyzer Fully Automated

      

5uL HPLC HbA1c Analyzer

      

Whole Blood HPLC HbA1c Analyzer

      
Best Fasting Diagnostic HPLC HbA1c Analyzer Fully Automated 5uL In Whole Blood Mode wholesale

Fasting Diagnostic HPLC HbA1c Analyzer Fully Automated 5uL In Whole Blood Mode Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Labnovation Technologies, Inc.
*Subject:
*Message:
Characters Remaining: (0/3000)